Readme for TWL-System Updater Version 1.4a

2010/03/04

Introduction

System Updater is a program for updating the System Menu (DSi Menu) of TWL development kits. It can be used on IS-TWL-DEBUGGER, IS-TWL-CAPTURE, and TWL test units. Because you can select any region while running the program, you can also use System Updater to switch the region setting of your development kits.

Note: System Updater was created with multi-region specifications, so it can be run on the development kits for all regions.

Notes

Please keep the following points in mind when using System Updater.

Procedure for Updating the System Menu (IS-TWL-DEBUGGER)

To update the System Menu of IS-TWL-DEBUGGER, follow this procedure.

  1. Power on the IS-TWL-DEBUGGER hardware and launch the IS-TWL-DEBUGGER software.
  2. Select FileLoad File, load SystemUpdater.srl, and execute a hardware reset.
  3. The IS-TWL-DEBUGGER software displays this message: SystemUpdater was loaded. Follow the LCD screen instructions.
  4. Use the IS-TWL-DEBUGGER hardware controller to select the applicable region.
  5. A confirmation screen displays the region you selected. Press the A Button to begin the update. DO NOT turn off the power before the update is completed.
  6. When the update ends successfully, the upper screen displays Update Success!. If the update fails, the upper screen displays Update Failure!. Contact [email protected] and provide the string displayed on the lower screen.
  7. Power off the IS-TWL-DEBUGGER hardware.
  8. Power on the IS-TWL-DEBUGGER hardware again and configure the DSi Menu initial settings. You cannot proceed with the initial settings if the touch screen's calibration information is invalid. In this case, display the calibration menu by restarting while holding down the L Button, R Button, and START. This allows you to calibrate the system.
  9. Start System Settings from the DSi Menu and confirm the DSi Menu version number shown in the lower-right portion of the upper screen.

Procedure for Updating the System Menu (IS-TWL-CAPTURE and TWL Test Units)

To update the System Menu of IS-TWL-CAPTURE or a TWL test unit, you must write SystemUpdater.srl to a TWL Flash Card.

  1. Power on the IS-TWL-DEBUGGER hardware and launch the IS-TWL-DEBUGGER software.
  2. Select FileLoad File and load SystemUpdater.srl. Do not select either of these options: Run TWL-CPUs after loading (X) or Reset TWL-CPUs after loading.
  3. Insert a TWL Flash Card into the IS-TWL-DEBUGGER hardware.
  4. Select ToolsDS Flash Card and write the loaded System Updater program to the TWL Flash Card.
  5. With System Updater written to the TWL Flash Card, insert the card into the IS-TWL-CAPTURE hardware or the TWL test unit. This same method can also be used to update the System Menu of IS-TWL-DEBUGGER hardware.
  6. Subsequent steps are the same as steps 4-8 of Procedure for Updating the System Menu (IS-TWL-DEBUGGER).

Version Number Notation

The version number is displayed in System Settings as follows ("*.*" indicates the version). Because the version number is used for development hardware, "_dev" is shown at the end.

Region Version Number Notation
Japan Ver *.*J_dev
America Ver *.*U_dev
Europe Ver *.*E_dev
Australia Ver *.*A_dev
China Ver *.*C_dev
Korea Ver *.*K_dev

System Updater Optional Features

System Updater has the following optional features.

Revision History

Revision Date Version Updated Content
2010/03/04 1.4a TwlNmenu and NandFiler were updated to the version included in TwlSDK 5.4.
[Korean version only] DSi camera was updated.
[Korean version only] Updated version data to Ver 1.4.1K_dev.
[Chinese version only] Updated version data to Ver 1.4.1C_dev.
2009/08/17 1.4 Added support for DSi Menu version 1.4. Updated TwlNmenu and NandFiler to versions bundled with TWL-SDK 5.3. Added China and Korea to the selectable regions.
2009/06/30 1.3a Added an option to update without installing TwlNmenu or NandFiler.
2009/04/28 1.3 Added support for DSi Menu version 1.3. Updated TwlNmenu and NandFiler to versions bundled with TWL-SDK 5.1 patch 4.
2009/01/15 1.2 Added support for DSi Menu version 1.2. Updated TwlNmenu and NandFiler to versions bundled with TWL-SDK 5.1 PR2.
2008/11/13 1.0c DSi Camera, DSi Sound, and the TWL-SDK tools TwlNmenu and NandFiler are now all installed by default.
2008/10/08 1.0b Added support for DSi Menu version 1.0.